Summary¶
Release 2.6.0 introduces a new climate entity for cooling mode per heating circuit (cooling_circuit), analogous to the existing heating_circuit entity. It shares the same current-room-temperature source but writes its setpoint to the dedicated cooling setpoint register. The feature is disabled by default and is enabled via a new option in the integration's Options Flow. No breaking changes.
New Features¶
Cooling Circuit Climate Entity (cooling_circuit)¶
Affected: custom_components/lambda_heat_pumps/climate.py · custom_components/lambda_heat_pumps/const_sensor.py
For each detected heating circuit, an additional entity can now be created alongside the heating circuit entity (climate.<prefix>_hc<n>_heating_circuit): climate.<prefix>_hc<n>_cooling_circuit.
- Current temperature: identical source as
heating_circuit(room_device_temperature, relative register address 4) - Target temperature: dedicated cooling setpoint register (
set_cooling_mode_room_temperature, relative register address 52) — e.g. register 5052 for HC1, 5152 for HC2, 5252 for HC3, … - HVAC mode:
cool(instead ofheatfor the heating circuit entity) - Temperature range: reuses the same options as the heating circuit (
heating_circuit_min_temp/heating_circuit_max_temp), since it's the same physical room
New entry in CLIMATE_TEMPLATES (const_sensor.py):
"cooling_circuit": {
"relative_address": 4, # room_device_temperature (same as heating_circuit)
"relative_set_address": 52, # set_cooling_mode_room_temperature
"name": "Cooling Circuit",
"unit": "°C",
"scale": 0.1,
"precision": 0.1,
"data_type": "uint16",
"firmware_version": 1,
"device_type": "hc",
"writeable": True,
"hvac_mode": {"cool"},
"state_class": "measurement",
},
The entity is created per heating circuit in async_setup_entry() (climate.py) — reusing the same central utility functions as the existing climate entities (generate_base_addresses, generate_sensor_names, build_subdevice_info, get_compatible_sensors).
New Option: Cooling Mode (cooling_mode_enabled)¶
Affected: custom_components/lambda_heat_pumps/config_flow.py · custom_components/lambda_heat_pumps/const_base.py
The integration's Options Flow now has a new "Cooling Mode" toggle (cooling_mode_enabled, default: Off). Only when enabled are the cooling_circuit entities created for all configured heating circuits:
if entry.options.get("cooling_mode_enabled", DEFAULT_COOLING_MODE_ENABLED):
for idx in range(1, num_hc + 1):
if "cooling_circuit" not in compatible_climates:
continue
entities.append(
LambdaClimateEntity(coordinator, entry, "cooling_circuit", idx, hc_addresses[idx], sensor_translations)
)
Translations¶
The new option and the new entity were added to both the German and English translations (translations/de.json, translations/en.json):
- Options Flow: label "Cooling Mode" / "Kühlbetrieb" with description text
- Entity name: "Cooling Circuit" / "Kühlkreis" (analogous to "Heating Circuit" / "Heizkreis")
Affected Files¶
| File | Change |
|---|---|
custom_components/lambda_heat_pumps/const_base.py |
New constant DEFAULT_COOLING_MODE_ENABLED = False |
custom_components/lambda_heat_pumps/const_sensor.py |
New CLIMATE_TEMPLATES entry cooling_circuit |
custom_components/lambda_heat_pumps/climate.py |
New per-heating-circuit entity creation (gated by cooling_mode_enabled); HVAC mode default and setpoint key mapping extended |
custom_components/lambda_heat_pumps/config_flow.py |
New boolean option cooling_mode_enabled in the Options Flow |
custom_components/lambda_heat_pumps/translations/de.json |
Translations added for option and entity |
custom_components/lambda_heat_pumps/translations/en.json |
Translations added for option and entity |