Release 2.8.0

Last updated: 2026-07-25

Current Release · Branch V2.8.0


Summary

Release 2.8.0 fixes four findings from Issue #100 (data corruption from implausible energy jumps, unfiltered Lambda sentinel raw values, a write-only register returning an invalid reading, and a firmware filter for general sensors that never actually worked) and introduces two new, generic mechanisms to support them: range notation for firmware_versions and opt-in sentinel values per sensor. It also fixes a race condition from Issue #105 that could cause PV-surplus and room-temperature writes to sporadically never reach the device, even though the log reported success. No breaking changes; all existing firmware_version: X sensors are unaffected.


New Features

Range notation for firmware versions (firmware_versions)

Affected: custom_components/lambda_heat_pumps/utils.py

Previously, a sensor template could only require a minimum firmware version ("firmware_version": X → active from version X onward, no upper bound). That's insufficient for registers that disappear again on newer controller generations (see finding below). New helper _parse_firmware_versions():

def _parse_firmware_versions(spec: list) -> set:
    """
    "X-Y"  -> range X to Y inclusive
    "-X"   -> exclude version X
    X      -> include version X (int)
    """

get_compatible_sensors() now checks, in this order:

  1. firmware_versions (range notation) — if present
  2. firmware_version (minimum, existing behavior) — if no firmware_versions
  3. Neither field → always active

Example: "firmware_versions": ["1-7"] — sensor only active for firmware integer 1 through 7, disappears from version 8 onward.

Opt-in sentinel values per sensor (sentinel_values)

Affected: custom_components/lambda_heat_pumps/utils.py, custom_components/lambda_heat_pumps/coordinator.py

is_sentinel_value() (see finding 2 below) only filters 0x8000 and the temperature-sensor-disconnected sentinel -3000 globally. -1 (0xFFFF) is deliberately not a global sentinel, since it's a legitimate reading for some sensors (e.g. temperature offsets). For registers where -1 genuinely means "not available", this can now be opted into per sensor template:

"sentinel_values": [65535],

is_sentinel_value(raw_value, data_type, extra_sentinels) checks this list in addition to the global sentinels.

Already applied to the defined request registers where -1 means "no request": buffer 3005-3009 (request_type, request_flow_line_temp_setpoint, request_return_line_temp_setpoint, request_heat_sink_temp_diff_setpoint, modbus_request_heating_capacity) and HC 5006 (operating_mode) — each with "sentinel_values": [65535]. All other buffer/HC sensors are unaffected.


Bug Fixes (#100)

Finding 1 — calculate_energy_delta clamped implausible jumps instead of discarding them

Affected: Energy consumption sensors on all heat pumps.

Symptom: After an implausible register jump (e.g. caused by a changed int32_register_order, see Release 2.7.0), the difference was clamped to max_delta and booked as real consumption — data corruption in the counter.

Fix: calculate_energy_delta() now returns None for a delta exceeding max_delta instead of clamping it. The caller in coordinator.py detects None, resets the reference reading to the current value, and books nothing.

Threshold extracted and tightened: max_delta used to be hardcoded as the literal 100.0 (kWh) in two places (the function default in utils.py and an explicit call in coordinator.py). Now single source of truth: MAX_ENERGY_DELTA_WH = 5000 in const_base.py (5 kWh instead of the previous 100 kWh). The coordinator.py call no longer passes max_delta explicitly, relying on the default instead. The value comes from an analysis in docs_md/ToDos/auto_32bit_register_handling.md: a real register-order flip jumps by multiples of 65,536 (typically several MWh), while realistic consumption jumps per update cycle are a few hundred Wh — 5000 Wh is well above normal consumption but far below any flip. Only this threshold was adopted; the full automatic flip-detection concept sketched there is not part of this release.

Affected files: custom_components/lambda_heat_pumps/const_base.py, custom_components/lambda_heat_pumps/utils.py, custom_components/lambda_heat_pumps/coordinator.py

Finding 2 — Lambda sentinel raw values were never filtered

Affected: All int16 registers, temperature sensors in particular.

Symptom: The Lambda Modbus protocol 1.0 defines sentinel raw values for "register not available" (32768 / 0x8000) and "sensor disconnected" (62536, -3000 as int16). These were previously scaled and stored unfiltered as real readings (e.g. a "temperature" of −300°C).

Fix: New function is_sentinel_value() checks the unscaled raw value before scale is applied. Affected sensors are set to None (→ entity unavailable), with an INFO log entry (raw value, register address, sensor ID). Applied at all five places where registers are read and scaled: batch read, single-register fallback, boiler, buffer, solar.

Affected files: custom_components/lambda_heat_pumps/utils.py, custom_components/lambda_heat_pumps/coordinator.py

Finding 4a — ambient_temperature (register 0002) returns an invalid reading on some firmware

Affected: Register 0002 (ambient_temperature), all firmware versions.

Symptom: Register 0002 is documented as write-only from a certain firmware generation onward (feeding in an external outdoor temperature) and returns 0xFFFF = −300°C when read. On older firmware, however, the register can return real temperature values — so removing the sensor outright would have been too blunt.

Fix: ambient_temperature is kept, but is now only available up to V0.0.9-3K (firmware integer 7) via "firmware_versions": ["1-7"], and additionally uses "sentinel_values": [65535] to filter 0xFFFF as "not available" specifically for this sensor — other sensors with a legitimate -1 value (e.g. temperature offsets) are unaffected.

Affected files: custom_components/lambda_heat_pumps/const_sensor.py

Affected: All general sensors (SENSOR_TYPES), including ambient_temperature.

Symptom: While implementing finding 4a it turned out the general sensor group (SENSOR_TYPES) — unlike HP/boiler/buffer/solar/heating-circuit sensors — was never passed through get_compatible_sensors(): neither for entity creation (sensor.py) nor for register reads (coordinator.py::_read_general_sensors_batch). A firmware_version/firmware_versions field on a general sensor therefore never had any effect, even before this release. Without this fix, the firmware range gating on ambient_temperature would have had no effect either.

Fix: sensor.py now creates general sensor entities via get_compatible_sensors(SENSOR_TYPES, fw_version); coordinator.py::_read_general_sensors_batch() now receives the filtered sensor list as a parameter instead of iterating SENSOR_TYPES directly.

Affected files: custom_components/lambda_heat_pumps/sensor.py, custom_components/lambda_heat_pumps/coordinator.py


Bug Fixes (#105)

PV-surplus / room-temperature writes could sporadically never reach the device

Affected: Users with PV-surplus or room-thermostat control enabled (periodic Modbus writes via services.py).

Symptom: The log regularly shows ✅ MODBUS WRITE SUCCESS, but the written value sporadically never arrives at the device.

Root cause: Before every write, wait_for_stable_connection() checks connection stability via a health-check read. This health check used its own, separate lock (_health_check_lock), while the actual coordinator reads and the writes themselves shared a different, common lock (_modbus_read_lock). Since the two locks didn't exclude each other, the health-check read could run concurrently with a real coordinator read or write on the same connection — which can desync Modbus transactions on the wire (Transaction ID collision, or on serial gateways a frame dropped due to overlap), so the write is reported successful at the protocol level while the device never actually applies the value. Made worse by two independent, unsynchronized timers (the write interval DEFAULT_WRITE_INTERVAL and the read interval DEFAULT_UPDATE_INTERVAL = 30), whose relative phase drifts through a collision window over time.

Fix: The health check now uses the same _modbus_read_lock as all other Modbus operations (async_read_holding_registers, async_read_input_registers, async_write_registers) — health checks, reads, and writes on a connection are now strictly serialized, regardless of the chosen timer intervals. The separate _health_check_lock was removed.

Affected files: custom_components/lambda_heat_pumps/modbus_utils.py


Affected Files

File Change
custom_components/lambda_heat_pumps/const_base.py MAX_ENERGY_DELTA_WH = 5000 new — single source of truth for the calculate_energy_delta threshold
custom_components/lambda_heat_pumps/modbus_utils.py _test_connection_health() now uses the shared _modbus_read_lock instead of a separate _health_check_lock (Issue #105)
custom_components/lambda_heat_pumps/utils.py _parse_firmware_versions() new; get_compatible_sensors() extended with range notation; calculate_energy_delta() returns None instead of max_delta, default from MAX_ENERGY_DELTA_WH; is_sentinel_value() new, with opt-in extra_sentinels parameter
custom_components/lambda_heat_pumps/coordinator.py Caller of calculate_energy_delta handles None and no longer passes max_delta explicitly; sentinel check (including template sentinel_values) before scaling in 5 places, with INFO log; _read_general_sensors_batch() receives the filtered sensor list as a parameter
custom_components/lambda_heat_pumps/sensor.py General sensor (SENSOR_TYPES) entity creation now uses get_compatible_sensors()
custom_components/lambda_heat_pumps/const_sensor.py ambient_temperature: "firmware_versions": ["1-7"] + "sentinel_values": [65535]; buffer request registers 3005-3009 (5 sensors) + HC 5006 (operating_mode): "sentinel_values": [65535]

Open (not part of this release)

  • Finding 3 (undocumented registers 1024–1060): Only 4 registers in this range (config_parameter_24/33/50/60) are actually undocumented placeholders. The firmware boundary for the new controller generation still needs clarification with the issue author; until then, sentinel filtering (finding 2) already protects against bad values.
  • Finding 4b (volume_flow_heat_sink unit/scale): Not yet implemented.

Details: ToDo document Issue #100.